Ground floor against earth — construction and radon protection

Capillary break layer, insulation and tight base slab against radon

2026-07-19·10 min reading

The ground floor is the building's floor against the earth, and it must cope with three things at once: stop rising damp, insulate against the cold and keep radon out. Here are the layers from bottom to top, the capillary break layer, the insulation, the U-value requirement and the radon barrier according to BR18 (max. 100 Bq/m³) and SBi 233.

Introduction

A ground slab is the floor construction that lies directly on the ground on the ground floor. It must solve three tasks at once: break the moisture that would otherwise rise from the ground, insulate so the floor is not cold and loses energy, and stop radon — a radioactive soil gas — from entering the home. The concrete pour itself is geometry (see the concrete article); here it is about the layers and tightness.

The layers from bottom to top

A typical ground floor slab is built up in a fixed sequence over prepared, compacted subgrade: a capillary break layer, insulation, concrete slab and finally floor covering (often with underfloor heating cast in). The exact structure depends on the project, but the principle — moisture break at bottom, insulation, tight slab at top — is consistent.

  • 01Shaped, compressed base: a stable, durable foundation without soft pockets.
  • 02Capillary break: a coarse material that stops rising ground moisture (see below).
  • 03Insulation: pressure-resistant insulation under (and possibly along the edge of) the concrete slab.
  • 04Concrete slab: the load-bearing, airtight surface — also the house's primary radon barrier.
  • 05Floor heating and covering: distributor layer/wearing layer with floor heating pipes and the visible floor covering.
Fig. Terrændæk i snit nedefra og op: komprimeret råjord, kapillarbrydende lag (≥ 150 mm), trykfast isolering (U ≤ 0,20), betonpladen som radonspærre og gulvvarme + belægning — randisolering bryder kuldebroen, og den tætte plade stopper radon (maks. 100 Bq/m³).

The capillary-breaking layer

Soil draws water upward by capillary action — like a sugar lump pulling coffee up. A capillary break layer is a coarse material with such large pores that the capillary force is broken and water cannot rise further up the structure. It is typically done with coarse, washed, capillary-breaking material (coarse gravel/pea gravel or lightweight clinker/leca).

Insulation and U-value

Terrændækket skal opfylde et U-værdikrav som resten af klimaskærmen. For nybyggeri er mindstekravet U ≤ 0,20 W/m²K, og ved renovering strammes det vejledende til ned mod U ≤ 0,10 W/m²K (se energiartiklen). Det kræver et tykt lag trykfast isolering (typisk EPS/XPS) under pladen. Langs ydervæggen bruges desuden randisolering for at bryde kuldebroen dér, hvor plade, fundament og ydervæg mødes.